The effect of photonic crystal fibre structure on the performance of Mach-Zehnder interferometer fibre optic gas sensors

Date

2020

Authors

Nazeri, Kaveh
Bradley, Colin

Journal Title

Journal ISSN

Volume Title

Publisher

Optical Fiber Technology

Abstract

A compact refractive index (RI) sensor, based on the Mach-Zehnder Interferometer (MZI), has been developed and experimentally evaluated for the highly sensitive detection and quantification of gases (Helium, Methane, and Carbon Dioxide). The RI sensor utilizes a variety of fibre types: Single Mode Fibre (SMF), Photonic Crystal Fibre (PCF), and Hollow-Core Photonic Crystal Fibre (HC-PCF). In order to fabricate the MZI sensors, a short length of sensing fibre was positioned between a lead-in and a lead-out single mode fibre (SMF) with an air gap at each interface. Three types of sensors were fabricated using this configuration employing 4 mm stub of: (i) PCF, (ii) 10 µm HC-PCF, and (iii) 20 µm HC-PCF as the sensing elements. The performance of these sensors, for detecting and measuring the quantity of gas present, were compared. The transmission spectrum of MZI sensors are formed by interference between the cladding and core modes. These transmission signals correspond to the frequency components in the sensor’s Fast Fourier Transform (FFT) spectrum. The effect of gap distance on the number and amplitude distribution of the modes was examined in an effort to optimize the design elements. The resulting fiber sensors can measure the RI of a gas-filled cavity and they showed high-sensitivity to helium, methane, and carbon dioxide. The highest RI sensitivity of 3210 nm/RIU was demonstrated in the RI range of 1.0000347-to-1.000449 by a sensor with a 4 mm long sensing stub element of 10 µm HC-PCF. Cyclic tests with the group of gases demonstrated that the measurements are highly repeatable. The measurement response and recovery times for all sensors were determined, and it was concluded that the 20 µm HC-PCF sensor has the fastest response/recovery time and the PCF sensor has the slowest. This research illustrates that the sensors fabricated by the proposed method have potential for improving the ability to detect and quantify pure gases. Additionally, the sensors are highly sensitive to low percentages of CO2, making them suitable for greenhouse gas measurement.

Description

Keywords

Mach-Zehnder interferometer, Refractive index sensor, Gas sensor, Photonic crystal fiber, Hollow-core PCF

Citation

Nazeri, K., & Bradley, C. (2020). The effect of photonic crystal fibre structure on the performance of Mach-Zehnder interferometer fibre optic gas sensors. Optical Fiber Technology, 58, 1-10. https://doi.org/10.1016/j.yofte.2020.102294.