Monitoring complex reactions using tandem mass spectrometric methods

dc.contributor.authorTing, Michelle Yan Chi
dc.contributor.supervisorMcIndoe, J. Scott
dc.date.accessioned2019-05-01T16:04:48Z
dc.date.available2019-05-01T16:04:48Z
dc.date.copyright2019en_US
dc.date.issued2019-05-01
dc.degree.departmentDepartment of Chemistry
dc.degree.levelMaster of Science M.Sc.en_US
dc.description.abstractSuzuki-Miyaura cross-coupling is a well-known method for making biaryls. With bifunctional monomers, Suzuki polycondensation (SPC) can be used to make polyaryls. Given the complexity of the reacting solution, studying the mechanism of SPC is extremely tough. To solve this problem, we used tandem mass spectrometric (MS/MS) methods to observe the dynamic behaviour of catalytically relevant species in real time. Catalysis involves a complex soup of reactants, intermediates and products. We used an ESI-MS with a triple quadrupole mass analyzer to monitor the SPC in positive ion mode using pressurized sample infusion (PSI) in real time. Full scan, selected ion recording (SIR), product ion scan, neutral loss scan (NLS) and multiple reaction monitoring (MRM) MS/MS methods were applied. Tetrakistriphenylphosphine palladium(0) was the catalyst of this reaction and a positively charged phosphonium aryl iodide tag (m/z 478) was implemented into the first catalytic cycle, enabling us to track all the intermediate oligomers up to the 4th addition. Product ion scan revealed all the intermediate oligomers lose a triphenylphosphine fragment (m/z 262) which would either come from the complex or the charged tag. Three significant intermediate types were observed in each stage of the catalysis, oxidative addition, transmetallation and reductive elimination and their behavior was studied in a chronogram, normalized to the total ion current. As expected, the use of selected ion recording, and neutral loss scan dramatically improved the signal-to-noise ratio. Ultimately, multiple reaction monitoring showed the best chronogram data due to the fact that this scan acts as a “double filter” in a soup of reactive species and contaminants. Real time reaction monitoring has proven to provide detailed insights regarding a reaction. MS/MS methods are promising for improving data quality, selectivity and sensitivity in reaction monitoring. The principle is broadly applicable to other systems, from an intricate catalytic reaction with short-lived ionic intermediates to a reaction with only a single product generated. Reaction dynamics for an exceptionally complex reaction can be made simple and easy by utilizing tandem mass spectrometry methods in time resolved reaction monitoring.en_US
dc.description.scholarlevelGraduateen_US
dc.identifier.urihttp://hdl.handle.net/1828/10816
dc.languageEnglisheng
dc.language.isoenen_US
dc.rightsAvailable to the World Wide Weben_US
dc.subjectMass spectrometryen_US
dc.subjectcatalysisen_US
dc.subjectESI-MSen_US
dc.subjectReaction Monitoringen_US
dc.subjectOrganometallicsen_US
dc.subjectOnline reaction monitoringen_US
dc.subjectPressurized sample infusionen_US
dc.titleMonitoring complex reactions using tandem mass spectrometric methodsen_US
dc.typeThesisen_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Ting_Michelle_MSc_2018.pdf
Size:
3.61 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: