Generation and application of Monte Carlo calculated beamlet dose distributions in radiation therapy

dc.contributor.authorBush, Karl Kenneth
dc.contributor.supervisorPopescu, Ioan Antoniu
dc.contributor.supervisorRoney, J. Michael
dc.date.accessioned2009-11-09T21:34:32Z
dc.date.available2009-11-09T21:34:32Z
dc.date.copyright2006en
dc.date.issued2009-11-09T21:34:32Z
dc.degree.departmentDepartment of Physics and Astronomy
dc.degree.levelMaster of Science M.Sc.en
dc.description.abstractThe use of beamlets as a dose calculation tool in Intensity Modulated Radiation Therapy (IMRT) treatment planning is widespread and well documented. A beamlet can simply be defined as the contribution of radiation passing through a particular geometrically defined subdivision of a given linear accelerator's emerging radiation field. The most common classes of algorithms used today to calculate the dose distributions deposited by beamlets are the pencil beam convolution and col-lapsed cone classes of algorithms. Using BEAMnrc [1], a Monte Carlo (MC) based radiation transport simulation software package, this thesis presents a novel method of calculating MC beamlet dose distributions with a level of accuracy not achievable using the above analytic dose calculation methods. In a first application, the MC beamlet dose distributions generated in this thesis are used to fine-tune the output of the MC or "virtual" linear accelerator from which they are produced. This is achieved through the adjustment of individual beamlet weights to align the output of the virtual accelerator to the experimentally measured output of the modeled accelerator in water. In a second application, MC beamlets are used to derive corrections to particular Multileaf Collimator (MLC) leaf sequences of IMRT treatment plans that have been miscalculated by a convolution-based dose calculation algorithm. These calculation inaccuracies (up to as much as 15%) arise due to the well known fact that convolution-based algorithms do not accurately model dose deposition in inhomoge¬neous media, such as lung [2] [3] [4]. In a final application, the MC beamlet generation method described in this thesis is implemented into a direct aperture optimization (DAO) algorithm. The implementation of MC beamlet generation in DAO forms the basis for a purely MC based inverse treatment planning system.en
dc.identifier.urihttp://hdl.handle.net/1828/1824
dc.languageEnglisheng
dc.language.isoenen
dc.rightsAvailable to the World Wide Weben
dc.subjectmedical physicsen
dc.subjectradiotherapyen
dc.subject.lcshUVic Subject Index::Sciences and Engineering::Health Sciences::Radiologyen
dc.subject.lcshUVic Subject Index::Sciences and Engineering::Physicsen
dc.titleGeneration and application of Monte Carlo calculated beamlet dose distributions in radiation therapyen
dc.typeThesisen

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
bush_karl_MSc_2006.pdf
Size:
36.19 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.83 KB
Format:
Item-specific license agreed upon to submission
Description: