dc.description.abstractAging is a primary determinant of cerebrovascular dysfunction, often marked by poor cerebrovascular reactivity to carbon dioxide. Traditional transcranial doppler ultrasound can measure cerebral artery CO2 reactivity, but is unable to provide volumetric quantification, because it can not image blood vessel diameter. In contrast, transcranial color coded duplex ultrasound (TCCS) provides volumetric hemodynamic measures that include velocity and diameter. Thus, using TCCS to insonate the middle cerebral artery (MCA) during a simple breath hold response test, we attempted to quantify if reliable volumetric MCA CO2 reactivity measures were achievable. We hypothesized that measuring volumetric, rather than velocity only reactivity would not impair reproducibility outcomes. Six healthy adults (29+-10), on visited the CHEERS laboratory and completed a breathhold response protocol on two separate visits (~24-hrs between visits). Diameter, velocity and blood flow were collected at rest, during 30-seconds of hyperventilation, 30-seconds of apneac breathing, and 30-seconds of recovery breathing. Between day resting MCA measures were not different, nor were MCA responses different during hyperventilation, breath hold, or recovery breathing. Collectively, TCCS is a reliable approach to measuring dynamic volumetric MCA responses during BHR, and future studies should incorporate volumetric hemodynamics assessments.en_US
dc.description.reviewstatusRevieweden_US
dc.description.scholarlevelUndergraduateen_US
dc.description.sponsorshipValerie Kuehne Undergraduate Research Awards (VKURA)en_US
dc.identifier.urihttp://hdl.handle.net/1828/14220
dc.language.isoenen_US
dc.subjectreproducibilityen_US
dc.subjectcerebrovascular healthen_US
dc.subjecthypercapnicen_US
dc.subjecthypocapniaen_US
dc.subjectnormocapnicen_US
dc.subjectbreath holden_US
dc.subjectvasodilationen_US
dc.subjectcerebral blood flowen_US
dc.subjectmiddle cerebral arteryen_US
dc.subjecttranscranial doppleren_US
dc.subjectdiameteren_US
dc.subjectvelocityen_US
dc.titleReproducibility of the simple cerebrovascular breath hold responses measured using transcranial color-coded doppler sonography?en_US
dc.typePosteren_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Jayda-Lauzon_VKURA_2022.pdf
Size:
663.43 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2 KB
Format:
Item-specific license agreed upon to submission
Description: