dc.description.abstractIn the past decade, the application of adaptive beamforming methods to medical ultrasound imaging has become a field of increased interest, due to their ability to achieve superior ultrasound image quality. Such enhancements, however, come at a high computational cost. This thesis attempts to address the following simple question: Can we maintain a superior image quality while reducing the computational cost of adaptive beamforming? Our goal is to effectively combine low-complexity nonadaptive beamforming, such as the Delay-and-Sum (DAS) technique, with high-complexity adaptive beamforming, such as the Minimum variance Distortionless Response (MVDR) technique, implemented using the Generalized Sidelobe Canceller (GSC), to obtain high-quality images at low computational cost. We propose a simple two-pass beamforming scheme for that purpose. During the first pass, our scheme processes buffered input vectors using the inexpensive DAS method and computes the corresponding envelope. Based on that envelope information, selected outputs may be recomputed during the second pass (to improve beamforming performance) using the expensive GSC beamforming method. The purpose of the first pass is to identify which nonadaptively beamformed outputs can be spared from a heavy computational load of adaptive beamforming taking place in the second pass. We have evaluated our scheme using simulated ultrasound images of a 12-point phantom and a point-scatterer-cyst phantom, achieving substantial threshold-dependent computational savings without significant degradation in image resolution and contrast, compared to pure GSC beamforming.en_US
dc.description.proquestemailrehoumahichem@gmail.comen_US
dc.description.scholarlevelGraduateen_US
dc.identifier.urihttp://hdl.handle.net/1828/8080
dc.languageEnglisheng
dc.language.isoenen_US
dc.rightsAvailable to the World Wide Weben_US
dc.subjectThesisen_US
dc.subjectMaster of Applied Scienceen_US
dc.subjectElectrical and Computer Engineeringen_US
dc.subjectUltrasound Imagingen_US
dc.titleEfficient two-pass beamforming applied to ultrasound imagingen_US
dc.typeThesisen_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Rehouma_Hichem_MASc_2017.pdf
Size:
2.08 MB
Format:
Adobe Portable Document Format
Description:
Master of Applied Science Thesis
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.74 KB
Format:
Item-specific license agreed upon to submission
Description: