The impact of dose calculation algorithms on partial and whole breast radiation treatment plans

dc.contributor.authorBasran, Parminder S.
dc.contributor.authorZavgorodni, Sergei
dc.contributor.authorBerrang, Tanya
dc.contributor.authorOlivotto, Ivo A.
dc.contributor.authorBeckham, Wayne
dc.date.accessioned2014-07-28T21:27:46Z
dc.date.available2014-07-28T21:27:46Z
dc.date.copyright2010en_US
dc.date.issued2010-12-16
dc.descriptionBioMed Centralen_US
dc.description.abstractBackground: This paper compares the calculated dose to target and normal tissues when using pencil beam (PBC), superposition/convolution (AAA) and Monte Carlo (MC) algorithms for whole breast (WBI) and accelerated partial breast irradiation (APBI) treatment plans. Methods: Plans for 10 patients who met all dosimetry constraints on a prospective APBI protocol when using PBC calculations were recomputed with AAA and MC, keeping the monitor units and beam angles fixed. Similar calculations were performed for WBI plans on the same patients. Doses to target and normal tissue volumes were tested for significance using the paired Student’s t-test. Results: For WBI plans the average dose to target volumes when using PBC calculations was not significantly different than AAA calculations, the average PBC dose to the ipsilateral breast was 10.5% higher than the AAA calculations and the average MC dose to the ipsilateral breast was 11.8% lower than the PBC calculations. For ABPI plans there were no differences in dose to the planning target volume, ipsilateral breast, heart, ipsilateral lung, or contra-lateral lung. Although not significant, the maximum PBC dose to the contra-lateral breast was 1.9% higher than AAA and the PBC dose to the clinical target volume was 2.1% higher than AAA. When WBI technique is switched to APBI, there was significant reduction in dose to the ipsilateral breast when using PBC, a significant reduction in dose to the ipsilateral lung when using AAA, and a significant reduction in dose to the ipsilateral breast and lung and contra-lateral lung when using MC. Conclusions: There is very good agreement between PBC, AAA and MC for all target and most normal tissues when treating with APBI and WBI and most of the differences in doses to target and normal tissues are not clinically significant. However, a commonly used dosimetry constraint, as recommended by the ASTRO consensus document for APBI, that no point in the contra-lateral breast volume should receive >3% of the prescribed dose needs to be relaxed to >5%.en_US
dc.description.reviewstatusRevieweden_US
dc.description.scholarlevelFacultyen_US
dc.identifier.citationBasran et al.: The impact of dose calculation algorithms on partial and whole breast radiation treatment plans. Radiation Oncology 2010 5:120.en_US
dc.identifier.urihttp://www.ro-journal.com/content/5/1/120
dc.identifier.urihttp://dx.doi.org/10.1186/1748-717X-5-120
dc.identifier.urihttp://hdl.handle.net/1828/5488
dc.language.isoenen_US
dc.publisherBioMed Centralen_US
dc.subject.departmentDepartment of Physics and Astronomy
dc.titleThe impact of dose calculation algorithms on partial and whole breast radiation treatment plansen_US
dc.typeArticleen_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Basran_PerminderS_RadiatOncol_2010.pdf
Size:
2.06 MB
Format:
Adobe Portable Document Format
Description:
Basran_PerminderS_RadiatOncol_2010.pdf
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.74 KB
Format:
Item-specific license agreed upon to submission
Description: