Development of a software based automatic exposure control system for use in image guided radiation therapy

dc.contributor.authorMorton, Daniel R
dc.contributor.supervisorJirasek, Andrew
dc.contributor.supervisorBeckham, Wayne
dc.date.accessioned2013-08-12T21:02:15Z
dc.date.available2013-08-12T21:02:15Z
dc.date.copyright2013en_US
dc.date.issued2013-08-12
dc.degree.departmentDepartment of Physics and Astronomy
dc.degree.levelMaster of Science M.Sc.en_US
dc.description.abstractModern image guided radiation therapy involves the use of an isocentrically mounted imaging system to take radiographs of a patient's position before the start of each treatment. Image guidance helps to minimize errors associated with a patients setup, but the radiation dose received by patients from imaging must be managed to ensure no additional risks. The Varian On-Board Imager (OBI) (Varian Medical Systems, Inc., Palo Alto, CA) does not have an automatic exposure control system and therefore requires exposure factors to be manually selected. Without patient specific exposure factors, images may become saturated and require multiple unnecessary exposures. A software based automatic exposure control system has been developed to predict optimal, patient specific exposure factors. The OBI system was modelled in terms of the x-ray tube output and detector response in order to calculate the level of detector saturation for any exposure situation. Digitally reconstructed radiographs are produced via ray-tracing through the patients' volumetric datasets that are acquired for treatment planning. The ray-trace determines the attenuation of the patient and subsequent x-ray spectra incident on the imaging detector. The resulting spectra are used in the detector response model to determine the exposure levels required to minimize detector saturation. Images calculated for various phantoms showed good agreement with the images that were acquired on the OBI. Overall, regions of detector saturation were accurately predicted and the detector response for non-saturated regions in images of an anthropomorphic phantom were calculated to generally be within 5 to 10 % of the measured values. Calculations were performed on patient data and found similar results as the phantom images, with the calculated images being able to determine detector saturation with close agreement to images that were acquired during treatment. Overall, it was shown that the system model and calculation method could potentially be used to predict patients' exposure factors before their treatment begins, thus preventing the need for multiple exposures.en_US
dc.description.proquestcode0760en_US
dc.description.proquestcode0574en_US
dc.description.proquestcode0756en_US
dc.description.scholarlevelGraduateen_US
dc.identifier.urihttp://hdl.handle.net/1828/4734
dc.languageEnglisheng
dc.language.isoenen_US
dc.rights.tempAvailable to the World Wide Weben_US
dc.subjectX-ray imagingen_US
dc.subjectAutomatic exposure controlen_US
dc.subjectimage guided radiation therapyen_US
dc.subjectmedical physicsen_US
dc.subjecton-board imagingen_US
dc.subjectdigitially reconstructed radiographsen_US
dc.titleDevelopment of a software based automatic exposure control system for use in image guided radiation therapyen_US
dc.typeThesisen_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Morton_Daniel_MSc_2013.pdf
Size:
3.8 MB
Format:
Adobe Portable Document Format
Description:
Thesis
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.74 KB
Format:
Item-specific license agreed upon to submission
Description: